TYPE='CRI FILE' VERSION='74' UNITS='US' SOURCE='PLS-CADD Version 13.20' USER='Power Line Systems, Inc.' FILENAME='\\nas\projects\nesc criteria\other files updated\1997_nesc_light_80mph_grade_b_method_a.cri' 1 ; m_iStringingDataWindDir I ; m_cStringingDataCondition 0(deg F) ; weather 20 'NESC Light' 0.05 0.00255858 8.99999 0 0 0 30 1 30 30 'None' '1' '1' 'Extreme Wind' 0 0.00255858 25.5858 0 0 0 60 1 60 60 'None' '1' '1' 'Extreme Ice' 0 0.00255858 0 0 0 57 30 1 30 30 'None' '1' '1' 'Uplift' 0 0.00255858 0 0 0 0 0 1 0 0 'None' '1' '1' 'Maximum Operating' 0 0.00255858 0 0 0 0 240 1 240 240 'None' '1' '1' 'NESC Blowout 6PSF' 0 0.00255858 6 0 0 0 60 1 60 60 'None' '1' '1' 'No Wind (SWING1)' 0 0.00255858 0 0 0 0 60 1 60 60 'None' '1' '1' 'Medium Wind (SWING 2)' 0 0.00255858 0.0639645 0 0 0 60 1 60 60 'None' '1' '1' 'High Wind (SWING 3)' 0 0.00255858 0.255858 0 0 0 60 1 60 60 'None' '1' '1' 'GALLOPING (SWING)' 0 0.00255858 1.99999 0.5 0 57 32 1 32 32 'None' '1' '1' 'GALLOPING (SAG)' 0 0.00255858 0 0.5 0 57 32 1 32 32 'None' '1' '1' '-20 Deg F' 0 0.00255858 0 0 0 0 -20 1 -20 -20 'None' '1' '1' '0 Deg F' 0 0.00255858 0 0 0 0 0 1 0 0 'None' '1' '1' '30 Deg F' 0 0.00255858 0 0 0 0 30 1 30 30 'None' '1' '1' '32 Deg F' 0 0.00255858 0 0.5 0 57 32 1 32 32 'None' '1' '1' '60 Deg F' 0 0.00255858 0 0 0 0 60 1 60 60 'None' '1' '1' '90 Deg F' 0 0.00255858 0 0 0 0 90 1 90 90 'None' '1' '1' '120 Deg F' 0 0.00255858 0 0 0 0 120 1 120 120 'None' '1' '1' '167 Deg F' 0 0.00255858 0 0 0 0 167 1 167 167 'None' '1' '1' '212 Deg F' 0 0.00255858 0 0 0 0 212 1 212 212 'None' '1' '1' ; cable_tension1 4 I 60 'NESC Light' 0 0 '' I 35 '60 Deg F' 0 0 '' C 25 '60 Deg F' 0 0 '' L 25 '60 Deg F' 0 0 '' ; autosag1 4 I 60 'NESC Light' 0 0 '' I 35 '60 Deg F' 0 0 '' C 25 '60 Deg F' 0 0 '' L 25 '60 Deg F' 0 0 '' ; struct_wgtspan 3 I 'Extreme Wind' I 'Uplift' I 'NESC Light' ; struct_wndwgtspan_report 4 I 'Extreme Wind' I 'NESC Light' I 'Uplift' I 'Extreme Ice' 14 ; Groups 'All' 'Built in group that all structures belong to' 1 0 0 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'Has DE' 'At least one dead end set on structure' 1 0 1 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'No DE' 'No dead end sets on structure' 1 0 2 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'All sets DE' 'All sets on structure are dead end' 1 0 3 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'Not all sets DE' 'At least one set on structure is not dead end' 1 0 4 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'Angle' 'Structure near nonzero line angle' 1 0 0 2 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'PLS-POLE' 'PLS-POLE created structure' 1 1 0 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'PLS-POLE has DE' 'PLS-POLE created structure with at least one dead end set' 1 1 1 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'PLS-POLE no DE' 'PLS-POLE created structure without any dead end sets' 1 1 2 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'PLS-POLE angle' 'PLS-POLE created structure near nonzero line angle' 1 1 0 2 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'TOWER' 'TOWER created structure' 1 2 0 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'TOWER has DE' 'TOWER created structure with at least one dead end set' 1 2 1 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'TOWER no DE' 'TOWER created structure without any dead end sets' 1 2 2 0 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' 'TOWER angle' 'TOWER created structure near nonzero line angle' 1 2 0 2 0 0 0 0 0 59 0.1 0 0 0 0 0 0 0 0 0 0 '' ; struct_loads 10 I 0 0.000000 1.5 2.5 1.65 1.5 1 0.65 1 0 0 0.9 0.65 0.65 0 1 'NESC Light' 'RULE 250B NA+' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 1 0.000000 1.5 2.5 1.65 1.5 1 0.65 1 0 0 0.9 0.65 0.65 0 1 'NESC Light' 'RULE 250B NA-' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 0 0.000000 1 2.5 1.65 1 1 0.65 1 0 0 0.9 0.65 0.65 0 1 'NESC Light' 'RULE 250B Uplift NA+' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 1 0.000000 1 2.5 1.65 1 1 0.65 1 0 0 0.9 0.65 0.65 0 1 'NESC Light' 'RULE 250B Uplift NA-' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 0 0.000000 1 1 1 1 1 0.75 1 0 0 0.9 0.75 0.75 0 1 'Extreme Wind' 'RULE 250C NA+' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 1 0.000000 1 1 1 1 1 0.75 1 0 0 0.9 0.75 0.75 0 1 'Extreme Wind' 'RULE 250C NA-' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 0 0.000000 1 1 1 1 1 0.65 1 0 0 0.9 0.65 0.65 1 1 'NESC Light' 'RULE 250B Insulators NA+' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 1 0.000000 1 1 1 1 1 0.65 1 0 0 0.9 0.65 0.65 1 1 'NESC Light' 'RULE 250B Insulators NA-' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 0 0.000000 1 1 1 1 1 1 1 0 0 1 1 1 1 1 'Extreme Ice' 'Extreme Ice NA+' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All I 1 0.000000 1 1 1 1 1 1 1 0 0 1 1 1 1 1 'Extreme Ice' 'Extreme Ice NA-' 1 0 0 'Pre V7 Standard' 0 0 '' -1 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 '' 0 0 1 ; Number of groups All ; struct_interact 10 I 'NESC Light' I 'NESC Light' I 'NESC Light' I 'NESC Light' I 'Extreme Wind' I 'Extreme Wind' I 'NESC Light' I 'NESC Light' I 'Extreme Ice' I 'Extreme Ice' ; vertical_clear 8 C 'Maximum Operating' L 'Maximum Operating' C 'Extreme Ice' L 'Extreme Ice' C 'NESC Light' L 'NESC Light' C 'NESC Blowout 6PSF' L 'NESC Blowout 6PSF' ; phase_clear 2 C 'Maximum Operating' C 'Maximum Operating' ; insul_swing 3 C 'No Wind (SWING1)' C 'Medium Wind (SWING 2)' C 'High Wind (SWING 3)' ; DepartureAngle 0 '60 Deg F' ; Weather Case for Final After Creep ; WC for final after load 1 'NESC Light' 0 ; old_global_section_display 'Maximum Operating' ; Global Display Weather Case C ; old_global_section_display_condition 0 ; old_global_section_color 1 ; m_iDrawClearanceLineCenterAndSideProf 345 ; clearance_voltage 0 ; old_draw_all_phases C ; asce_terrain_type 1 ; use_actual_max_tension 1 ; true_weight_span 10 705 NESC Light per Rule 250B, Page 148 80 MPH Extreme Wind Loading per Rule 250C, Page 148 Grade B Construction "Method A" per Table 253-1, Page 155 and Table 261-1A, Page 163 Tension Limits per Rule 261H2, Page 161 Insulator Strength Reduction per Rule 277, Page 170 Should be applied to Insulator Strengths when Modeling Insulators 1997 NESC C2-1997 Criteria File for PLS-CADD Created May 17, 2001 POWER LINE SYSTEMS, INC. IS NOT RESPONSIBLE FOR THE ACCURACY OF THE CONTENT HEREIN. THIS FILE IS BEING PROVIDED AS A REFERENCE. CRITERIA SHOULD BE CHECKED AND MODIFIED AS NECESSARY BY A QUALIFIED ENGINEER FAMILIAR WITH THE NESC REQUIREMENTS OF THE AREA WHICH THE PROJECT IS IN AND ITS APPLICATION. CC 1 0 'GALLOPING (SWING)' 'GALLOPING (SAG)' ;galloping 0 0 3 1.000000 0 0.000000 0.000000; galloping 0 ; m_iOuterStrandsCompression ; cExportSapsSagsecLoads 0 0 ; iBogus 0 ; iBogus 0 ; dBogus 0 ; dBogus 0 ; dBogus 2 ; iSapsLevel 0 ; rgdStiffness[i][j] 0 ; rgdStiffness[i][j] 0 ; rgdStiffness[i][j] 0 ; rgdStiffness[i][j] 0 ; rgdStiffness[i][j] 0 ; rgdStiffness[i][j] 0 ; iNoL4Towers 0 ; iNoL4Symetrical 0 ; iStrippedL4Towers 0 ; iNoL3Towers 15.55555556 ; m_dDefaultWireTemp I ; m_cDefaultWireCondition 6.89474e+010 ; m_dACSRMaxCompressiveStress 2 ; m_iUKNNATerrainType 1 ; m_dUKNNAReliabilityLevelPartialFactor 1 ; m_dUKNNAShapeFactor 0 ; m_iUKNNAComputeGRFForInsulator 0.1 ; m_dSAPSWindPower 10.0584 ; m_dSAPSWindRefHeight 2 ; m_iCenelecTerrainType B ; m_cIECTerrainType 1 ; m_dIECIcedDragCoeff 0 ; m_iIECApplyWindOnIce 1 ; m_iSectionSortOrder 100 ; m_dTPNZSecLenForLite 2 ; m_dTPNZTerrainType 1 ; m_dTPNZIcedDragCoeff 1 ; m_dTPNZWindPressureUnitAction 0 ; m_iSagTenReportFE -1.111111111 ; m_dStringChartTempStart 21.11111111 ; m_dStringChartTempStop 5.555555556 ; m_dStringChartTempInc I ; m_cStringChartCondition 0 ; m_iStringChartIncludeConcentratedLoads 3 ; m_nStringChartWaves 1 ; m_dCB1IcedDragCoeff 1 ; m_iCBTerrainTypeAndRegion 1 ; m_iStrLoadsReportIncCri 1 ; m_iStrLoadsReportIncSpanLoads 1 ; m_iStrLoadsReportIncStructLoads 1 ; m_iStrLoadsReportIncMoments 1 ; m_iStrLoadsReportIncWind 0 ; m_iStrLoadsReportIncJntLbl 1 ; m_iStrLoadsReportIncSetPhase 256 ; m_iStrLoadsReportPicWidth 256 ; m_iStrLoadsReportPicHeight 1 ; m_iStrLoadsReportIncWires 0 ; m_iStrLoadsReportIncStructLoadsCondensed 0 ; m_iStatnettLoadsReport 0 ; m_iStrLoadsReportIncGroups -1 ; m_iStrCommentForWireWindVelFactor -1 ; m_iStrCommentForWireIceLoadFactor -1 ; m_iStrCommentForStrWindVelFactor 0 ; m_iStrLoadsReportIncDebug -1 ; m_iStrCommentForWireIceThickFactor A ; m_cRussiaTerrainCategory 1.6 ; m_dRussiaStructureGRF ; Load Train 0 0 ; m_iLoadTrainPositionRestriction 0 ; m_dClearanceLineVerticalBuffer 1 ; m_iDrawClearanceLineSpikes 0 ; iLowestWireOnly ; Wire Clearance Line 0 1 ; m_iDisplayProfWireClearLine 1 ; m_iDisplayPlanWireClearLine 1 ; m_iDisplayPPProfWireClearLine 1 ; m_iDisplayPPPlanWireClearLine ; EN50341-3-9:2001 UK NNA Minimum and Maximum Ice Thickness Limits 0 0 ; m_iClearWindRamp ; tree_clear 8 C 'Maximum Operating' L 'Maximum Operating' C 'Extreme Ice' L 'Extreme Ice' C 'NESC Light' L 'NESC Light' C 'NESC Blowout 6PSF' L 'NESC Blowout 6PSF' 1 ; iTreeGrowIn 1 ; iTreeFall 0 ; iTreeDbg 1 ; iTreeReportGraphics 0 ; iTreeMarkerSagLine 0 ; iTreeMarkerWirePoints 0 ; iTreeMarkerPointsConsidered 0 ; iTreeRadial 0 ; iTreeReportDest 2 ; iTreeReportViolationsOnly 300 10 ; dTreeRootBallRadius 0 ; dTreeReqFallClear 3.048 ; dTreeMaxHorizSepForGround 16711935 ; &rgbTreeFall 65535 ; &rgbTreeFallInvalidGround 255 ; &rgbTreeGrow 0 ; m_iStatnettEnableBundleIceFactor 5 ; m_dStatnettBundleMinIceLoad 25 ; m_dStatnettBundleMaxIceLoad 1 ; m_dStatnettBundleMinIceLoadFactor 0.6 ; m_dStatnettBundleMaxIceLoadFactor 0 ; m_iClearRadialCheck 0 ; m_iClearReportType 0 ; m_dMaxOffsetFromWire 0 ; m_dClearTinMaxWireOffset 0 ; m_dClearCenterlineStationInterval 0 ; m_dClearTinStationInterval 0 ; project->criteria.m_iDrawWireMarkersInClearanceCommands 0 ; m_iClearOutlineViolationTriangles 1 ; m_iClearReportGraphicsInReport 0 ; m_iClearReportViolationsOnlyInReport 0 ; m_iClearWireTin 0 ; m_cClearanceDialogSettings.m_iClearSagLine1 0 ; m_cClearanceDialogSettings.m_iClearClearBox 2 ; m_cClearanceDialogSettings.m_emtViolationMarkers 0 ; m_cClearanceDialogSettings.m_iWirePoints 0 ; m_cClearanceDialogSettings.m_iClearPosConsidered 1 ; m_iASNZS70002010TerrainTypeAndRegion 1 ; m_dASNZS70002010IcedDragCoeff 100 ; m_dASNZS70002010SecLenForLite 0 ; m_bApplyNescConstantToEachIndependentWireAsPer2012 1 ; m_dREE_RDD_223_2008_InsulWindPressureFactor 1 ; m_iSapsModelChainedInsulatorsL2L3 'C' 0 260 3.048 9.144 0.9144 1 1 1 1 1 0 0 2 ; rating parms 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 600 400 1 0 300 400 1 0 0.01745329252 ; m_dAngleIncrementeLCWD_360 0 ; m_sldSectionLoadDistribution 0 ; m_iUKNNAWindAdjustWithHeightVersion 1 ; m_eIS802TerrainCategory 1.2 ; m_dIS802GroundWireDragCoeff 0 ; m_dIS802TemperatureForHeightAdjust 0 ; m_iCSAIceGroundWireMode 1 ; m_dCSAIceGroundWireFactor 1.3 ; m_dCSAIceSpatialFactor 1.15 ; m_dCSAIceHeightFactor 0 ; m_iCSAWantConductorSpecificAfterLoadWC 0 ; m_iIsecTerrainType